Intratester Reliability and Validity of Concentric Measurements Using a New Hand-Held Dynamometer
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
پیش نمایش صفحه اول مقاله
Intratester Reliability and Validity of Concentric Measurements Using a New Hand-Held Dynamometer
چکیده انگلیسی

Janssen JC, Le-Ngoc L. Intratester reliability and validity of concentric measurements using a new hand-held dynamometer.ObjectiveTo assess the reliability of a new hand-held dynamometer (HHD) to perform concentric measurements, and to determine the agreement between the HHD and the criterion standard isokinetic dynamometer.DesignElbow flexion concentric measurements were performed on a mechanical arm using the HHD and the isokinetic dynamometer.SettingEngineering laboratory and university strength-testing facility.ParticipantsThree patient profiles, differing in range of motion (ROM) and strength, were simulated by a mechanical arm.InterventionsNot applicable.Main Outcome MeasuresPeak torque and ROM obtained from concentric elbow flexion profiles.ResultsIntratester reliabilities, measured with the intraclass correlation coefficient (ICC1,1), of the peak torque and start and end ROM are excellent for both the HHD (.99, .98, and .99, respectively) and the isokinetic dynamometer (.99 for all 3 variables). The angle of peak torque was rated fair to good in intrareliability for both devices, at .64 (HHD) and .69 (isokinetic dynamometer). Validity, measured within the limits of agreement (LOA) between the 2 devices, was clinically acceptable for peak torque and start ROM, although not for end ROM and angle of peak torque.ConclusionsIt is possible to use the new HHD to obtain dynamic measurements of joint motion. Intratester reliability of the HHD is excellent and is in clinical acceptable agreement with the isokinetic dynamometer for peak torque and start ROM. End ROM was, however, not in agreement because of a systematic error in the isokinetic dynamometer measurement for 1 of the 3 tested profiles. Intratester reliabilities of the angle of peak torque were fair to good for both the HHD and isokinetic dynamometer, but the LOA were not clinically acceptable. Stability of the arm and speed of measurement might be confounding factors in this study.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Archives of Physical Medicine and Rehabilitation - Volume 90, Issue 9, September 2009, Pages 1541–1547
نویسندگان
, ,