کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3451935 1595774 2008 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Poststroke Upper-Limb Rehabilitation Using 5 to 7 Inserted Microstimulators: Implant Procedure, Safety, and Efficacy for Restoration of Function
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
پیش نمایش صفحه اول مقاله
Poststroke Upper-Limb Rehabilitation Using 5 to 7 Inserted Microstimulators: Implant Procedure, Safety, and Efficacy for Restoration of Function
چکیده انگلیسی

Davis R, Sparrow O, Cosendai G, Burridge JH, Wulff C, Turk R, Schulman J. Poststroke upper-limb rehabilitation using 5 to 7 inserted microstimulators: implant procedure, safety, and efficacy for restoration of function.ObjectiveTo investigate the feasibility of implanting microstimulators to deliver programmed nerve stimulation for sequenced muscle activation to recover arm-hand functions.DesignBy using a minimally invasive procedure and local anesthesia, 5 to 7 microstimulators can be safely and comfortably implanted adjacent to targeted radial nerve branches in the arm and forearm of 7 subjects with poststroke paresis. The microstimulators' position should remain stable with no tissue infection and can be programmed to produce effective personalized functional muscle activity with no discomfort for a preliminary 12-week study. Clinical testing, before and after the study, is reported in the accompanying study.SettingMicrostimulator implantations in a sterile operating room.ParticipantsSeven adults, with poststroke hemiparesis of 12 months or more.InterventionUnder local anesthesia, a stimulating probe was inserted to identify radial nerve branches. Microstimulators were inserted by using an introducer and were retrievable for 6 days by attached suture. Each device was powered via a radiofrequency link from 2 external cuff coils connected to a control unit.Main Outcome MeasuresTo achieve low threshold values at the target sites with minimal implant discomfort. Microstimulators and external equipment were monitored over 12 weeks of exercise.ResultsSeven subjects were implanted with 41 microstimulators, 5 to 7 per subject, taking 3.5 to 6 hours. Implantation pain levels were 20% more than anticipated. No infections or microstimulator failures occurred. Mean nerve thresholds ranged between 4.0 to 7.7μcoulomb/cm2/phase over 90 days, indicating that cathodes were within 2 to 4mm of target sites. In 1 subject, 2 additional microstimulators were inserted.ConclusionsMicrostimulators were safely implanted with no infection or failure. The system was reliable and programmed effectively to perform exercises at home for functional restoration.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Archives of Physical Medicine and Rehabilitation - Volume 89, Issue 10, October 2008, Pages 1907–1912
نویسندگان
, , , , , , ,