Therapeutic Effectiveness of Electric Stimulation of the Upper-Limb Poststroke Using Implanted Microstimulators
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
پیش نمایش صفحه اول مقاله
Therapeutic Effectiveness of Electric Stimulation of the Upper-Limb Poststroke Using Implanted Microstimulators
چکیده انگلیسی

Turk R, Burridge JH, Davis R, Cosendai G, Sparrow O, Roberts HC, Hughes A-M, Schulman J. Therapeutic effectiveness of electric stimulation of the upper-limb poststroke using implanted microstimulators.ObjectiveTo investigate the therapeutic effect of functional exercise augmented by programmable implanted microstimulators on arm and hand function.DesignBefore and after study.SettingImplantation was performed in a neurosurgery unit, systems were programmed, and tests were conducted in a university laboratory and subjects exercised at home.ParticipantsHemiparetic subjects (N=7) with reduced upper-limb function who were at least 12 months poststroke were recruited from the community. No subjects withdrew.InterventionMicrostimulators were implanted into the arms and forearms to activate elbow, wrist, and finger extension, and thumb abduction. After training and programming of the system, subjects underwent 12 weeks of functional home-based exercise with stimulation.Main Outcome MeasuresThe primary functional measure was the Action Research Arm Test (ARAT). Impairment measures included upper-limb Fugl-Meyer Assessment (FMA) and tests of motor control (tracking index), spasticity (electromyography stretch index) strength, and active range of motion (AROM). The assessor was not blinded, but scores were validated by an independent blinded observer.ResultsAll subjects were able to perform functional activities at home by using the system. Compliance was excellent, and there were no serious adverse events. Statistically significant improvements were measured (P<.05) in the tracking index (57.3°2±48.65°2), FMA score (6.3±3.59), wrist-extensor strength (5.5±4.37N), and wrist AROM (19.3°±18.96°). The mean improvement in ARAT score ± SD of 4.9±7.89 was not statistically significant.ConclusionsThis study has shown the feasibility of a programmable implanted microstimulator system used at home to perform functional exercises and a reduction in impairment after 12 weeks.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Archives of Physical Medicine and Rehabilitation - Volume 89, Issue 10, October 2008, Pages 1913–1922
نویسندگان
, , , , , , , ,