کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3459722 1231185 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of Normal Adrenal Gland Volume by 64-slice CT
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
پیش نمایش صفحه اول مقاله
Evaluation of Normal Adrenal Gland Volume by 64-slice CT
چکیده انگلیسی

ObjectiveTo measure volume and other parameters of normal adrenal glands in Chinese adults with 64-slice multidetector CT, to evaluate the relationship of volume result with age, sex and body size, and to explore the correlations between adrenal volume and other measurements.MethodsThis study was based on 125 acquired contrast-enhanced upper abdominal CT scans performed with a 64-slice CT. The final study group consisted of 81 patients (49 males, 32 females). Portal venous phase images were studied for the measurements. Both the reconstruction interval and thickness were 1.5 mm. Each adrenal gland was outlined manually with computer-assistant technology to calculate its volume. The maximal sectional area, length, width and thickness of each adrenal gland were also measured.ResultsThe mean age of total population was 47.9±13.0 (range: 20–76) years. The left, right, and total adrenal gland volumes were 4.23±0.74 (range: 2.85–5.83) cm3, 4.26±0.86 (2.59–6.56) cm3, and 8.50±1.40 (5.80–11.39) cm3, respectively. These volumes increased with weight (r=0.381, 0.389, and 0.437 respectively, all P<0.001), height (r=0.386, P<0.001; r=0.297, P=0.007; r=0.384, P<0.001) and body surface area (r=0.406, 0.392, and 0.452, all P<0.001). There was no significant difference in left, right or total adrenal volume with regard to sex after applying General Linear Model procedure to reduce the impact of weight (F =1.304, 0.064, and 0.597, all P>0.05), nor did volume change significantly with age (r=−0.033, −0.014, and −0.026, all P>0.05). Nearly all descriptors of bilateral adrenal glands correlated with ipsilateral volume except thickness (r=−0.027, P=0.814) and width (r=0.166, P=0.138) in the left side. Among these parameters, length had a stronger correlation with volume than others in the both left (r=0.412, P<0.001) and right (r=0.516, P<0.001) adrenal glands.ConclusionOur study has defined the volume distribution and other parameters of normal adrenal glands in Chinese adults, which provide a baseline for future studies.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chinese Medical Sciences Journal - Volume 27, Issue 4, December 2012, Pages 220-224