کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3498156 1234437 2007 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
پیش نمایش صفحه اول مقاله
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial
چکیده انگلیسی

SummaryBackgroundCoronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents.MethodsWe enrolled 63 patients (44 men; mean age 61·3 [SD 9·5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 monthsFindings71 stents, 10–15 mm in length and 3·0–3·5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61·5 (SD 13·1%) to 12·6 (5·6%) with an acute gain of 1·41 mm (0·46 mm) and in-stent late loss of 1·08 mm (0·49 mm). The ischaemia-driven target lesion revascularisation rate was 23·8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48·4 (17·0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis.InterpretationThis study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: - Volume 369, Issue 9576, 2–8 June 2007, Pages 1869–1875
نویسندگان
, , , , , , , , , , , , , , , ,