ResumenObjetivoHay varios métodos para determinar hemoglobina glucosilada A1c (HbA1c), tanto rápidos para punto de uso en la consulta como de laboratorio. Nuestro objetivo ha sido comparar la concordancia diagnóstica entre 2 métodos de detección de HbA1c.Material y métodosSe realizó un estudio descriptivo transversal de concordancia diagnóstica en el Centro de Salud Los Cármenes. Se incluyeron de forma consecutiva 2 grupos de pacientes con y sin diabetes mellitus tipo 2. Se compararon un método en punto de uso para consulta externa (DCATM Systems Siemens®) con otro de laboratorio (análisis cromatográfico). Se estudiaron la concentración de HbA1c y la concordancia entre los métodos con el coeficiente de correlación intraclase (CCI, A1) y con el método de Bland-Altman.ResultadosSe estudió a 102 pacientes, 62 diabéticos (60,8%) y 40 no diabéticos (39,2%). La media global ± desviación estándar de porcentaje de HbA1c fue de 6,46 ± 0,88 en el análisis con sangre capilar mediante sistema DCA™ y de 6,44 ± = 0,86 en el análisis del laboratorio (p > 0,05). El grado de acuerdo entre las 2 pruebas fue de 0,975 (intervalo de confianza del 95%, 0,963-0,983). La media de la diferencia entre las determinaciones de las 2 pruebas evaluadas fue de 0,024 ± 0,27. El porcentaje de puntos fuera de los límites de acuerdo óptimo definidos en el gráfico de Bland-Altman fue del 2,5%.ConclusionesLa concordancia diagnóstica entre un método para punto de uso en consulta y uno de laboratorio ha sido muy alta. La detección en punto de uso permite una rápida y sencilla valoración de la concentración de HbA1c.
ObjectiveSeveral methods are available for measuring glycosylated A1c hemoglobin (HbA1c), all rapid methods for point of care use in a clinical or laboratory setting. This study attempts to compare the diagnostic agreement between two methods for detection of HbA1c.Material and methodsA descriptive cross-sectional study of diagnostic agreement was carried out in the Los Carmenes Health Centre. Two groups of patients -with and without type 2 diabetes- were consecutively included. A method for point-of-care use in a Primary Care Clinic setting (DCATM Systems Siemens®) was compared with a laboratory test (chromatographic analysis). An analysis was made of the mean concentration of HbA1c, the agreement between methods, using the intra-class correlation coefficient (CCLA1) and the Bland-Altman method.ResultsA total of 102 patients were included, 62 diabetic (60.8%) and 40 non-diabetic (39.2%). The overall mean HbA1c was 6.46% (SD = 0.88) in the analysis using capillary blood in the clinic with the DCA™ system, and 6.44% (SD = 0.86) using the laboratory test (P>.05). The degree of agreement between the two tests was 0.975 (95% CI: 0.963-0.983). The mean of the differences between the results of the two assessed tests was 0.024 (SD = 0.27). The percentage of points outside the limits of optimal agreement, as defined in the Bland-Altman graph, was 2.5%.ConclusionsDiagnostic agreement between a method for point-of-care use in a Primary Health Care Clinic and a laboratory test was very high. Detection at the point-of-care allows a quick and simple assessment of HbA1c.
Journal: SEMERGEN - Medicina de Familia - Volume 40, Issue 8, November–December 2014, Pages 431–435