کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3849627 1598319 2010 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Peritoneal Dialysis Outflow Failure From Omental Wrapping Diagnosed by Catheterography
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری‌های کلیوی
پیش نمایش صفحه اول مقاله
Peritoneal Dialysis Outflow Failure From Omental Wrapping Diagnosed by Catheterography
چکیده انگلیسی
Peritoneal dialysis outflow failure caused by omental wrapping is a serious complication that is difficult to diagnose noninvasively. We report a case of outflow failure in which catheterography showed several characteristics of omental wrapping: “pseudocele” formation, delayed catheter emptying, and uneven distribution of contrast in the abdominal cavity. A laparoscopic procedure was performed with identification of peritoneal adhesion and greater omental wrapping. The catheter was stripped from the omentum and repositioned in the Douglas peritoneal sac. Catheterography is a reliable, safe, noninvasive, and inexpensive alternative procedure to diagnose outflow failure caused by omental wrapping.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Journal of Kidney Diseases - Volume 56, Issue 5, November 2010, Pages 1006-1011
نویسندگان
, , , ,