کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3863888 1598916 2013 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparative Effectiveness Review: Prostate Cancer Antigen 3 Testing for the Diagnosis and Management of Prostate Cancer
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری‌های کلیوی
پیش نمایش صفحه اول مقاله
Comparative Effectiveness Review: Prostate Cancer Antigen 3 Testing for the Diagnosis and Management of Prostate Cancer
چکیده انگلیسی

PurposeWe compared the effectiveness of PCA3 (prostate cancer antigen 3) and select comparators for improving initial or repeat biopsy decision making in men at risk for prostate cancer, or treatment choices in men with prostate cancer.Materials and MethodsMEDLINE®, EMBASE®, Cochrane Database and gray literature were searched from January 1990 through May 2012. Included studies were matched, and measured PCA3 and comparator(s) within a cohort. No matched analyses were possible. Differences in independent performance estimates between PCA3 and comparators were computed within studies. Studies were assessed for quality using QUADAS (Quality Assessment of Diagnostic Accuracy Studies) and for strength of evidence using GRADE (Grading of Recommendations Assessment, Development and Evaluation) criteria.ResultsAmong 1,556 publications identified, 34 observational studies were analyzed (24 addressed diagnostic accuracy and 13 addressed treatment decisions). Most studies were conducted in opportunistic cohorts of men referred for procedures and were not designed to answer key questions. Two study biases (partial verification and sampling) were addressed by analyses, allowing some conclusions to be drawn. PCA3 was more discriminatory than total prostate specific antigen increases (eg at an observed 50% specificity, summary sensitivities were 77% and 57%, respectively). Analyses indicated that this finding holds for initial and repeat biopsies, and that the markers were independent predictors. For all other biopsy decision making comparisons and associated health outcomes, strength of evidence was insufficient. For treatment decision making, strength of evidence was insufficient for all outcomes and comparators.ConclusionsPCA3 had a higher diagnostic accuracy than total prostate specific antigen increases, but strength of evidence was low (limited confidence in effect estimates). Strength of evidence was insufficient to conclude that PCA3 testing leads to improved health outcomes. For all other outcomes and comparators, strength of evidence was insufficient.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Urology - Volume 190, Issue 2, August 2013, Pages 389–398
نویسندگان
, , , , ,