کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3915659 1251515 2007 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Pharmacokinetic study to compare the absorption and tolerability of two doses of levonorgestrel following single vaginal administration of levonorgestrel in Carraguard® gel: a new formulation for “dual protection” contraception
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی زنان، زایمان و بهداشت زنان
پیش نمایش صفحه اول مقاله
Pharmacokinetic study to compare the absorption and tolerability of two doses of levonorgestrel following single vaginal administration of levonorgestrel in Carraguard® gel: a new formulation for “dual protection” contraception
چکیده انگلیسی

ObjectiveThe study was conducted to assess levonorgestrel (LNG) serum levels achieved after a single administration of two different doses of Carraguard vaginal gel containing LNG (CARRA/LNG), designed for use as microbicide and contraceptive for potential dual protection.Materials and MethodsThis was a randomized double-blind pharmacokinetic study conducted in 12 subjects enrolled at two centers. Each subject received a single vaginal administration of CARRA/LNG containing either 0.75 or 1.5 mg LNG per 4 mL of gel on Days 10–12 of the menstrual cycle. LNG serum levels were measured at 0, 1, 2, 4, 8 and 12 h after administration and for the following 7 days. LH and progesterone (for a preliminary evaluation of effect on the ovarian function) as well as SHBG were measured in the daily samples.ResultsSerum LNG maximum concentrations (Cmax) were 14.1±2.1 and 11.7±2.7 nmol/L and Tmax was 12.0 and 6.0 h for the low and high dose, respectively, with large intersubject variability within the first 48 h. Mean levels at 96 h were 10% of Cmax. Differences in AUC between both doses were not statistically significant. SHBG levels decreased approximately 25% by Day 4 after administration. Luteal activity was observed in 3/6 and 5/6 of the subjects in the low- and high-dose group, respectively.ConclusionThis study demonstrates that the CARRA/LNG gel can sustain elevated serum levels of the contraceptive steroid for up to 96 h after a single application. The serum levels attained with the 0.75-mg formulation are in the range expected to perturb the ovulatory process as observed in some subjects. The lack of correlation between the administered dose and serum concentrations of the steroid may be related to a rate-limiting absorption of LNG from the vaginal mucosa. The results reported here suggest that the CARRA/LNG formulation has good potential to become a dual-protection method, possibly preventing conception and sexually transmitted infections.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Contraception - Volume 75, Issue 6, June 2007, Pages 454–460
نویسندگان
, , , , , , , , , ,