ObjectiveThe objective of this study is to clarify whether the isovolumetric contraction time obtained from Doppler cardiography (Doppler ICT) can be an index substituted for fetal cardiac contractility.Materials and methodsIn 10 pregnant ewes, fetal hypoxemia was induced by giving a variable mixture of gases. Through experiment, the Doppler ICT, pre-ejection period (PEP), and the maximum first derivative of the left ventricular pressure waveform (Max dp/dt) were simultaneously recorded every 10 min. The relationship between both the Doppler ICT and PEP, and the Max dp/dt were analyzed.ResultsA significant negative linear regression was founded between the Doppler ICT and the Max dp/dt. A significant negative linear regression was also shown between PEP and the Max dp/dt. Moreover, the regression of Max dp/dt on ICT had significantly less residual variance than the regression of Max dp/dt on PEP (p = 0.0004).ConclusionIn contrast to PEP, Doppler ICT is a reliable, and non-invasive index which can be substituted for fetal cardiac contractility.
Journal: Early Human Development - Volume 83, Issue 4, April 2007, Pages 263–267