کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3921817 1599877 2008 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Vaginal prolapse repair surgery augmented by ultra lightweight titanium coated polypropylene mesh
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی زنان، زایمان و بهداشت زنان
پیش نمایش صفحه اول مقاله
Vaginal prolapse repair surgery augmented by ultra lightweight titanium coated polypropylene mesh
چکیده انگلیسی

ObjectivesTo determine the safety and efficacy of ultra lightweight titanium coated polypropylene mesh to augment conventional vaginal prolapse repair in women with recurrent symptomatic prolapse stage II or more or primary prolapse stage III or more.Study designA prospective observational cohort study was performed at two urogynecological centres in The Netherlands. Women with recurrent symptomatic prolapse at least stage II or primary vaginal prolapse ICS POP stage III or more participated in the study. POP-Q and validated urogynecological questionnaires were used pre- and post-operatively. Outcome measures were mesh-related morbidity and prolapse recurrence, defined as ICS POP stage II, as well as changes in domain scores on urogenital distress- and defaecatory distress inventory (UDI and DDI), incontinence impact questionnaire (IIQ) as well as sexual functioning. Wilcoxon's signed ranks test for paired variables and 95% confidence intervals, respectively were used to analyse these data.ResultsThe study group comprised 71 patients with a median follow-up of 9 months (6–14). Mesh erosions were detected in four patients (5.6%), all on the posterior vaginal wall. After Ti-mesh® augmentation in 14 patients (36%) the anterior vaginal wall and in 7 patients (18%) the posterior vaginal wall, was categorised as ICS POP stage II and were thus considered failures. UDI and DDI domain scores all improved significantly, except for the domains of incontinence and pain, respectively. Three out of five domains of the IIQ showed significant improvement. Surgery did not have any significant negative impact on sexual functioning.ConclusionUltra lightweight titanized polypropylene mesh to augment conventional vaginal prolapse repair surgery showed minimal morbidity, but no additional value compared to conventional surgery at short-term follow-up.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Obstetrics & Gynecology and Reproductive Biology - Volume 138, Issue 2, June 2008, Pages 232–238
نویسندگان
, , , , , ,