کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
3922562 | 1599901 | 2006 | 6 صفحه PDF | دانلود رایگان |
ObjectivesTo evaluate the efficacy and safety of a surgical treatment for stress urinary incontinence by implantation of a silicone-coated polyester tape (Lift®).Materials and methodsThis retrospective study included 72 female patients having had a suburethral silicone-coated polyester tape inserted as treatment for stress urinary incontinence, combined or not with pelvic surgery. We recorded the patient's characteristics, the surgical procedure, the short and long-term results and complications.ResultsSeventy-two patients were operated, 60 of whom were fully evaluated. The average follow-up was 17 months. On 48 patients (80%) the treatment was successful, 3 (5%) were improved, and 9 (15%) were regarded as a failure. Dysuria occurred in six (10%) patients, five were de novo, and one was persistent. Ten patients (16.6%) presented de novo urge incontinence. The main complication was a higher rate of severe infections, accompanied by defective healing (4, i.e. 6.7%).ConclusionThe procedure using a silicone-coated polyester tape seems to be efficient, but insufficiently secure. This higher rejection rate leads us to prefer other synthetic materials proved to be better tolerated.
Journal: European Journal of Obstetrics & Gynecology and Reproductive Biology - Volume 126, Issue 1, 1 May 2006, Pages 107–112