کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
3939958 | 1253574 | 2007 | 9 صفحه PDF | دانلود رایگان |

ObjectiveTo evaluate operative resectoscopy versus hysteroscopic bipolar electrode excision for the treatment of endometrial polyps.DesignProspective, randomized study.SettingTertiary-care university hospital.Patient(s)One hundred consecutive patients with endometrial polyps.Intervention(s)Patients underwent diagnostic hysteroscopy, and after assignment on a random basis, they underwent polyp excision either by operative resectoscopy or by a bipolar electrode passed through the operating sheath of a small-caliber hysteroscope.Main Outcome Measure(s) and Result(s)Operating times, difficulty of the operation, surgeon satisfaction with the procedure, intra- and postoperative complications, postoperative pain, and patient satisfaction were recorded. The two procedures did not differ in total surgery times. In subgroup analysis, the resectoscope was faster for large polyps (>2 cm) and for polyps with a fundal implant. The bipolar electric probe was faster for small polyps (<2 cm) and for polyps with a nonfundal implant.Conclusion(s)Operative resectoscopy appears to be the technique of choice for endometrial polyps >2 cm or with a fundal implant. Bipolar electrode excision appears to be preferable for smaller, nonfundal polyps.
Journal: Fertility and Sterility - Volume 87, Issue 4, April 2007, Pages 909–917