کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3947035 1254401 2011 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Incidence of mechanical malfunction in low-profile subcutaneous implantable venous access devices in patients receiving chemotherapy for gynecologic malignancies
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی زنان، زایمان و بهداشت زنان
پیش نمایش صفحه اول مقاله
Incidence of mechanical malfunction in low-profile subcutaneous implantable venous access devices in patients receiving chemotherapy for gynecologic malignancies
چکیده انگلیسی

ObjectiveThe purpose of this study was to investigate the incidence of mechanical complications associated with low-profile subcutaneous implantable venous access devices in gynecologic oncology patients.MethodsGynecologic oncology patients with low-profile Port-a-Caths implanted between March 2005 and July 2006 were identified into a computerized database. Patient demographics, operative complications, number of chemotherapy cycles, duration of implantation, and mechanical complications were collected. Primary outcomes included port leakage, catheter fracture, and catheter embolization.Results112 patients underwent 115 Port-a-Cath placements with low profile single-lumen plastic ports with Groshong-valved catheters. Mean Port-a-Cath indwelling duration was 197 days (range: 4–395) with a mean number of 12 chemotherapy cycles (range 0–64). The cumulative complication rate necessitating removal or replacement was 15%. Of the 14 Port-a-Caths removed, ten (8.7%) were secondary to mechanical malfunction: one for leakage at the port site, two for catheter fracture, and seven for fracture with catheter embolization to the heart or pulmonary vasculature—most commonly the right ventricle. Patients with embolization were asymptomatic and all embolized catheters were successfully retrieved by interventional radiology without complications.ConclusionsThe rates of catheter fracture and embolization have previously been reported to be low in patients with subcutaneous Port-a-Caths, and have not been studied in patients receiving low-profile subcutaneous Port-a-Caths. This study suggests that catheter fracture may be more common (8.7%) and must be considered in patients with malfunctioning low-profile Port-a-Caths. Embolized catheters can be removed by interventional radiology without significant adverse affects.


► Mechanical malfunction of low-profile subcutaneous implantable catheters has not been reported in the general oncology literature.
► Our data suggest an increased rate of the following mechanical malfunctions of low-profile implantable Port-a-Caths: catheter leakage, fracture, and embolization.
► Embolized catheters can be retrieved by interventional radiology without morbidity.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gynecologic Oncology - Volume 123, Issue 1, October 2011, Pages 54–57
نویسندگان
, , , , , , , ,