کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3956637 1255320 2013 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Two- and Three-Dimensional Ultrasonography and Sonohysterography versus Hysteroscopy With Laparoscopy in the Differential Diagnosis of Septate, Bicornuate, and Arcuate Uteri
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی زنان، زایمان و بهداشت زنان
پیش نمایش صفحه اول مقاله
Two- and Three-Dimensional Ultrasonography and Sonohysterography versus Hysteroscopy With Laparoscopy in the Differential Diagnosis of Septate, Bicornuate, and Arcuate Uteri
چکیده انگلیسی

Study ObjectiveTo estimate the diagnostic accuracy and to compare the diagnostic value of 3-dimensional sonohysterography (3D-SIS), 3-dimensional transvaginal ultrasonography (3D-TVS), 2-dimensional sonohysterography (2D-SIS), and 2-dimensional transvaginal ultrasonography (2D-TVS) (initial and expert diagnosis) in the differential diagnosis of septate, bicornuate, and arcuate uteri.DesignProspective clinical study (Canadian Task Force II-2).SettingUniversity hospital and private hospital and clinic.PatientsA total of 117 women with a history of recurrent abortions or infertility and a 2D-TVS initial diagnosis of a septate, bicornuate, or arcuate uterus.InterventionsExpert 2D-TVS, 3D-TVS, 2D-SIS, and 3D-SIS performed by experienced examiners and hysteroscopy with laparoscopy to establish the final diagnosis.Measurements and Main ResultsHysteroscopy performed in conjunction with laparoscopy (HL) detected 23 arcuate, 60 septate, 22 bicornuate, and 12 normal uteri. 3D-SIS showed perfect diagnostic accuracy (100.0%) in general detection of uterine abnormalities, compared with initial 2D-TVS (77.8%), expert 2D-TVS (90.6%), 2D-SIS (94.0%), and 3D-TVS (97.4%). In the overall diagnosis of uterine anomalies, all of the diagnostic methods had statistically significantly better diagnostic value than initial 2D-TVS (p < .001), whereas 3D-SIS was the only method that was better than expert 2D-TVS (p < .001).ConclusionsAlthough 3D-SIS was identical to HL, with the highest accuracy, there was no significant difference in diagnostic value between 3D-TVS with 2D-SIS and 3D-SIS or between expert 2D-TVS and 3D-TVS with 2D-SIS. The high diagnostic value of these ultrasonographic tools questions the need for endoscopy in the differential diagnosis of the most common congenital uterine anomalies.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Minimally Invasive Gynecology - Volume 20, Issue 1, January–February 2013, Pages 90–99
نویسندگان
, , , , ,