کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3962601 1255662 2007 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Small-diameter hysteroscopy with Versapoint versus resectoscopy with a unipolar knife for the treatment of septate uterus: A prospective randomized study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی زنان، زایمان و بهداشت زنان
پیش نمایش صفحه اول مقاله
Small-diameter hysteroscopy with Versapoint versus resectoscopy with a unipolar knife for the treatment of septate uterus: A prospective randomized study
چکیده انگلیسی

Study objectiveTo compare 2 procedures for metroplasty: resectoscopy with monopolar knife versus small-diameter hysteroscopy fitted with a Versapoint device.DesignProspective randomized study (Canadian Task Force classification I).SettingEndoscopic gynecology units at tertiary care university hospitals.PatientsOne hundred-sixty patients with septate uterus and a history of recurrent abortion or primary infertility undergoing hysteroscopic metroplasty from 2001 to 2005.InterventionsHysteroscopic resection of the uterine septum performed with either a 26F resectoscope with unipolar knife (80 women, group A) or a 5-mm diameter hysteroscope with Versapoint device (80 women, group B). All patients were managed expectantly, with follow-up lasting 1 year.Measurements and main resultsOperative parameters (operative time, fluid absorption, complications, need for second intervention) and reproductive outcome parameters (pregnancy, abortion, term and preterm delivery, modality of delivery, cervical cerclage) were measured. Operative time and fluid absorption were significantly greater in group A than in group B (23.4 ± 5.7 vs 16.9 ± 4.7 minutes and 486.4 ± 170.0 vs 222.1 ± 104.9 mL, respectively). The cumulative complication rate was significantly lower in group B than in group A. No difference in any of the reproductive parameters was observed between the 2 groups: pregnancy and delivery rates were 70% and 81.6% in group A vs 76.9% and 84% in group B. Nine women (18.4%) from group B and 8 women (16%) from group B experienced spontaneous abortions. Most patients (54/82) delivered by cesarean section without differences according to the hysteroscopic technique used for metroplasty (65% in group A vs 67.7% in group B) or to the gestational age (65.1% of term and 68.7% of preterm deliveries).ConclusionsSmall-diameter hysteroscopy with bipolar electrode for the incision of uterine septum is as effective as resectoscopy with unipolar electrode regarding reproductive outcome and is associated with shorter operating time and lower complication rate.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Minimally Invasive Gynecology - Volume 14, Issue 5, September 2007, Pages 622–627
نویسندگان
, , , , , , ,