کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4001800 1602113 2016 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Visual Outcomes and Accommodative Response of the Lumina Accommodative Intraocular Lens
ترجمه فارسی عنوان
نتایج دیداری و پاسخ مکانی لنز داخلی لومینا
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی چشم پزشکی
چکیده انگلیسی

PurposeTo compare visual acuity, accommodation, and contrast sensitivity of the AkkoLens Lumina accommodative intraocular lens (AkkoLens Clinical b.v., Breda, The Netherlands) with a standard monofocal intraocular lens (IOL).DesignRandomized clinical trial.MethodsThe study enrolled 86 eyes with cataract that all required cataract surgery and IOL implantation. The study group included 61 eyes that were implanted with the Lumina. The control group included 25 eyes that were implanted with an Acrysof SA60AT (Alcon, Fort Worth, TX, USA) monofocal IOL. The distance and near visual acuities, contrast sensitivity, and accommodation were measured over a 1-year follow-up period. Accommodation was measured subjectively, using defocus curves, and objectively, with an open-field autorefractor.ResultsUncorrected (UDVA) and corrected (CDVA) distance visual acuities did not differ significantly between the groups (P ≥ .21) over the 12 months. However, the uncorrected near visual acuity (UNVA) was 0.07 ± 0.08 logRAD for the Lumina group and 0.37 ± 0.19 logRAD for the control group (P < .01) and the corrected distance near visual acuity (CDNVA) was 0.11 ± 0.12 LogRAD for the Lumina group and 0.41 ± 0.15 LogRAD for the control group (P < .01). Defocus curves showed a statistically significant difference between groups for defocus ranging from −4.50 to −0.50 diopters (D) (P < .01) with significantly higher visual acuities for the Lumina group. Subjective accommodation, as determined from defocus curves, was 3.05 ± 1.06, 3.87 ± 1.27, and 5.59 ± 1.02 D for the Lumina group and 1.46 ± 0.54, 2.00 ± 0.52, and 3.67 ± 0.75 D for the control group at visual acuities of 0.10, 0.20, and 0.4 logMAR for both groups, respectively. The objective accommodation, measured by an open-field autorefractor, was 0.63 ± 0.41, 0.69 ± 0.45, 0.91 ± 0.51, and 1.27 ± 0.76 D for the Lumina group and 0.10 ± 0.15, 0.12 ± 0.15, −0.06 ± 0.09 and 0.07 ± 0.10 D for the control group at accommodation stimuli of 2.0, 2.5, 3.0, and 4.0 D, respectively. Contrast sensitivity was the same for both groups (P ≥ .26).ConclusionsThe Lumina accommodative IOL effectively restores the visual function, accommodation, and contrast sensitivity after cataract surgery with no influence on the postoperative contrast sensitivity.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Journal of Ophthalmology - Volume 164, April 2016, Pages 37–48
نویسندگان
, , , , , , ,