کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
400369 1438721 2016 16 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Impact of energy storage system on load frequency control for diverse sources of interconnected power system in deregulated power environment
ترجمه فارسی عنوان
تأثیر سیستم ذخیره انرژی بر کنترل فرکانس بار برای منابع متنوع سیستم قدرتمند متصل در محیط قدرت کنترل نشده
کلمات کلیدی
کنترل فرکانس بار، واحد تولید چند منبع، محیط قدرت محروم، سیستم ذخیره انرژی ثبات سیگنال کوچک
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر هوش مصنوعی
چکیده انگلیسی


• Combination of multisource power generation is used for LFC studies.
• RFB energy storage device is incorporated for improvement of dynamic response.
• The small signal stability study has been done for interconnected system.
• Deregulated environment has been considered.
• OHS optimization algorithm has been used for design the optimal controller.

This paper focuses Load Frequency Control (LFC) mechanism for multi-generating two areas interconnected power systems with energy storage system in a deregulated power environment. The two areas, demarcated as Area-I and Area-II, consist of thermal, hydro and gas power units. This paper also incorporates the economic load dispatch mechanism into the LFC for economical division of load during load deviation. Small signal stability analysis through participating factor has also been done to determine the oscillation state of the system, i.e., frequency deviation in both areas. Therefore, proper controller is required to reduce the oscillation of the system. The optimum value of the integral gain of the integral controller has to be selected to achieve the goal. Hence, Opposition-based Harmonic Search (OHS) technique is used for the optimization purpose. During major disturbance in the areas, primary and secondary controllers are not sufficient to reduce the frequency and tie-line power oscillation due to slow response of the governor mechanism. Therefore, energy storage system, i.e., Redox Flow Battery (RFB), is used for improvement of the dynamic response of the system which has very small time constant and quick response. The proposed control mechanism has been analyzed in a deregulated power environment with the help of different simulation case studies to find out improved dynamic performance over integral control strategies.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Electrical Power & Energy Systems - Volume 79, July 2016, Pages 11–26
نویسندگان
, , ,