کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4016540 1261955 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of the predictability of refractive cylinder correction by laser in situ keratomileusis in eyes with low or high ocular residual astigmatism
ترجمه فارسی عنوان
مقایسه پیشبینی تصحیح سیلندر انکساری با استفاده از لیزر در کراتومیلیوس در چشم با آستیگماتیسم باقی مانده کمر یا بالا
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی چشم پزشکی
چکیده انگلیسی

PurposeTo compare the manifest refractive cylinder (MRC) predictability of myopic astigmatism laser in situ keratomileusis (LASIK) between eyes with low and high ocular residual astigmatism (ORA).SettingLondon Vision Clinic, London, United Kingdom.DesignRetrospective case study.MethodsThe ORA was considered the vector difference between the MRC and the corneal astigmatism. The index of success (IoS), difference vector ÷ MRC, was analyzed for different groups as follows: stage 1, low ORA (ORA ÷ MRC <1), high ORA (ORA ÷ MRC ≥1); stage 2, low ORA group reduced to match the high ORA group for MRC; stage 3, grouped by ORA magnitude with low ORA (<0.50 diopters [D]), mid ORA (0.50 to 1.24 D), and high ORA (≥1.25 D); stage 4, high ORA group subdivided into low (<0.75 D) and high (≥0.75 D) corneal astigmatism.ResultsFor stage 1, the mean preoperative MRC and mean IoS were −1.32 D ± 0.65 (SD) (range −0.55 to −3.77 D) and 0.27, respectively, for low ORA and −0.79 ± 0.20 D (range −0.56 to −2.05 D) and 0.37, respectively, for high ORA. For stage 2, the mean IoS increased to 0.32 for low ORA. For stage 3, the mean IoS was 0.28, 0.29, and 0.31 for low ORA, mid ORA, and high ORA, respectively. For stage 4, the mean IoS was 0.20 for high ORA/low corneal astigmatism and 0.35 for high ORA/high corneal astigmatism.ConclusionsThe MRC predictability was slightly worse in eyes with high ORA when grouped by the ORA ÷ MRC. Matching for the MRC and grouping by ORA magnitude resulted in similar predictability; however, eyes with high ORA and high corneal astigmatism were less predictable.Financial DisclosureDr. Reinstein is a consultant to Carl Zeiss Meditec AG, has a proprietary interest in the Artemis technology (Arcscan, Inc.), and is an author of patents related to very-high-frequency digital ultrasound administered by the Center for Technology Licensing at Cornell University, Ithaca, New York, USA. No other author has a financial or proprietary interest in any material or method mentioned.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cataract & Refractive Surgery - Volume 41, Issue 7, July 2015, Pages 1383–1392
نویسندگان
, , , , ,