کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4017510 1261978 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Initial evaluation of a femtosecond laser system in cataract surgery
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی چشم پزشکی
پیش نمایش صفحه اول مقاله
Initial evaluation of a femtosecond laser system in cataract surgery
چکیده انگلیسی

PurposeTo report the early experience and complications during cataract surgery with a noncontact femtosecond laser system.SettingHong Kong Sanatorium and Hospital, Hong Kong Special Administrative Region, China.DesignRetrospective case series.MethodsAll patients had anterior capsulotomy or combined anterior capsulotomy and lens fragmentation using a noncontact femtosecond laser system (Lensar) before phacoemulsification. Chart and video reviews were performed retrospectively to determine the intraoperative complication rate. Risk factors associated with the complications were also analyzed.ResultsOne hundred seventy eyes were included. Free-floating capsule buttons were found in 151 eyes (88.8%). No suction break occurred in any case. Radial anterior capsule tears occurred in 9 eyes (5.3%); they did not extend to the equator or posterior capsule. One eye (0.6%) had a posterior capsule tear. No capsular block syndrome developed, and no nuclei were dropped during irrigation/aspiration (I/A). Anterior capsule tags and miosis occurred in 4 eyes (2.4%) and 17 eyes (10.0%), respectively. Different severities of subconjunctival hemorrhages developed in 71 (43.8%) of 162 eyes after the laser procedure. The mean surgical time from the beginning to the end of suction was 6.72 minutes ± 4.57 (SD) (range 2 to 28 minutes).ConclusionsCataract surgery with the noncontact femtosecond laser system was safe. No eye lost vision because of complications. Caution should be taken during phacoemulsification and I/A to avoid radial anterior capsule tears and posterior capsule tears.Financial DisclosureDr. Chang received travel expenses from Abbott Medical Optics, Inc., and Technolas Perfect Vision GmbH and lecture honoraria from Abbott Medical Optics, Inc., Technolas Perfect Vision GmbH, and Alcon Laboratories, Inc. Dr. Chang was a consultant to Abbott Medical Optics, Inc., from 2010 to 2011. No author has a financial or proprietary interest in any material or method mentioned.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cataract & Refractive Surgery - Volume 40, Issue 1, January 2014, Pages 29–36
نویسندگان
, , , , , ,