کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4020116 1262029 2006 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی چشم پزشکی
پیش نمایش صفحه اول مقاله
Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography
چکیده انگلیسی

PurposeTo measure total corneal power using optical coherence tomography (OCT).SettingRefractive surgery practices at 2 academic eye centers in Cleveland, Ohio, and Los Angeles, California, USA.MethodsThirty-two eyes of 17 patients having myopic laser in situ keratomileusis (LASIK) were enrolled in a prospective observational study. Manifest refraction, OCT, and Placido ring corneal topography with the Atlas 995 (Carl Zeiss Meditec, Inc.) were performed preoperatively and 3 months after laser in situ keratomileusis (LASIK). A high-speed (2000 axial scans/second) corneal and anterior segment OCT prototype was used. The total corneal power was calculated by summation of the anterior and posterior surface powers, and the value was compared with that determined by simulated keratometry. Two methods of measuring total corneal power were tested: the direct method, which used OCT to measure both corneal surfaces directly, and the hybrid method, which combined OCT with anterior corneal topography.ResultsThe repeatability (pooled standard deviation) of measuring total corneal power using the hybrid method was 3 times better than that using the direct method. It was 0.23 diopter (D) before LASIK and 0.26 D after LASIK. Preoperative total power was 1.13 D (2.6%) lower than the simulated keratometry. Compared to the LASIK-induced change in spherical equivalent refraction, the change in total corneal power was equivalent, while the change in simulated keratometry power was significantly smaller (−18.8%) (P<.001).ConclusionsKeratometry using the traditional index of 1.3375 overestimated the total power in preoperative corneas and underestimated LASIK-induced refractive change. Measuring both corneal surfaces using a combination of OCT and Placido ring topography provided a better measure of total corneal power that closely tracked the refractive change in post-LASIK eyes.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cataract & Refractive Surgery - Volume 32, Issue 11, November 2006, Pages 1843–1850
نویسندگان
, , , ,