PurposeTo determine the diagnostic yield of tests commonly used for vitreous fluid analysis in eyes with suspected intraocular infection or malignancy.DesignNoncomparative interventional case series.ParticipantsForty-four consecutive patients (45 eyes) treated from 1998 through 2006 with posterior segment inflammation who underwent pars plana vitrectomy for diagnostic purposes.InterventionVitreous specimens obtained via pars plana vitrectomy were analyzed by microbiologic culture, cytologic analysis, and flow cytometry.Main Outcome MeasuresDiagnostic yield and sensitivity of each test performed on vitreous specimens and visual outcomes of eyes that underwent diagnostic vitrectomy (DVx).ResultsPreoperative diagnoses were infection in 15 eyes and malignancy in 30 eyes. Overall, vitreous analysis identified a specific cause in 9 (20%) of 45 eyes. The overall sensitivity of DVx was 63.6%. The sensitivities of individual tests were: culture, 50%; cytologic analysis, 66.7%; and flow cytometry, 83.3%. The yields of diagnostic tests were: culture, 5.7%; cytologic analysis, 14.3%; and flow cytometry, 20.6%. Final diagnoses were infection in 6 eyes, malignancy in 9 eyes, and idiopathic in 30 eyes. Mean visual acuity improved significantly in the first 6 months after DVx. Visual acuity improved in 60% of eyes, with 37.8% of eyes improving by 3 lines or more.ConclusionsAnalysis of vitreous fluid by widely available tests is useful in identifying intraocular infection or malignancy. Most patients experienced a substantial improvement in vision.
Journal: Ophthalmology - Volume 114, Issue 10, October 2007, Pages 1893–1897