کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4055542 1603851 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The test–retest reliability and minimal detectable change of spatial and temporal gait variability during usual over-ground walking for younger and older adults
ترجمه فارسی عنوان
قابلیت اطمینان مجدد تست و حداقل تغییر قابل توجه تغییر متغیر قیمتی مکانی و زمانی در طی پیاده روی معمولی بیش از حد زمین برای سالمندان جوان و سالخوردگان
کلمات کلیدی
قابلیت اطمینان، راه رفتن، تغییرپذیری، جوانتر مسن تر
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی


• We compared test–retest reliability of gait variability between young and old.
• We examined minimal detectable change (MDC) of gait variability for young and old.
• ICCs provide limited information due to restricted ranges in young adults.
• Based on absolute reliability young had greater reliability compared to old.
• Young had smaller MDC in all gait variability compared to old except step width.

Gait variability is a marker of gait performance and future mobility status in older adults. Reliability of gait variability has been examined mainly in community dwelling older adults who are likely to fluctuate over time. The purpose of this study was to compare test–retest reliability and determine minimal detectable change (MDC) of spatial and temporal gait variability in younger and older adults. Forty younger (mean age = 26.6 ± 6.0 years) and 46 older adults (mean age = 78.1 ± 6.2 years) were included in the study. Gait characteristics were measured twice, approximately 1 week apart, using a computerized walkway (GaitMat II). Participants completed 4 passes on the GaitMat II at their self-selected walking speed. Test–retest reliability was calculated using Intra-class correlation coefficients (ICCs(2,1)), 95% limits of agreement (95% LoA) in conjunction with Bland-Altman plots, relative limits of agreement (LoA%) and standard error of measurement (SEM). The MDC at 90% and 95% level were also calculated. ICCs of gait variability ranged 0.26–0.65 in younger and 0.28–0.74 in older adults. The LoA% and SEM were consistently higher (i.e. less reliable) for all gait variables in older compared to younger adults except SEM for step width. The MDC was consistently larger for all gait variables in older compared to younger adults except step width. ICCs were of limited utility due to restricted ranges in younger adults. Based on absolute reliability measures and MDC, younger had greater test–retest reliability and smaller MDC of spatial and temporal gait variability compared to older adults.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gait & Posture - Volume 44, February 2016, Pages 94–99
نویسندگان
, , , , ,