کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4080973 1267574 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Small diameter metal-on-metal total hip arthroplasty at 13 years – a follow-up study
ترجمه فارسی عنوان
قطعه بر روی فلزی بر روی آرتروپلاستی در 13 سال ؟؟ یک مطالعه پیگیری
کلمات کلیدی
آرتروپلاستی لگن کامل، بلبرینگ فلز بر روی فلز
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

IntroductionTheoretically, the properties of second-generation metal-on-metal (MoM) bearings are better for wear, osteolysis and longevity. However, follow-up studies of more than 10 years are rare, in particular with hybrid fixation (cemented stainless steel stems and cementless cup), therefore we evaluated the results of this combination after a mean follow-up of 12.8 years: (1) to analyze the survival rate, (2) to compare it with the survival rate in the same series after 6.4 years (95.8% cup, 94.8% stem), (3) to evaluate clinical and radiographic outcome and (4) to analyze these failures.HypothesisThe number of revisions would increase after 10 years.Materials and methodsWe evaluated 106 total hip arthroplasties (THA) (Cedior™ press-fit cup with cemented Acora™ (n = 50) and Exafit™ (n = 56) stems and 28 mm Metasul™ bearings performed between January 1999 and December 2002. The survival rate was calculated by the Kaplan-Meier method. The clinical assessment included the Postel Merle d’Aubigné (PMA) and Oxford scores. The radiographic assessment evaluated radiolucencies and osteolysis on standard X-rays. A histological analysis was only performed during revision THA.ResultsAfter a mean 12.8 years of follow-up (10–16), 53 THA were reviewed in 48 patients. Thirteen THA revisions (14%) were performed including 11 aseptic revisions (5 stem fractures, 2 cases of impingement and 3 loosenings [1 bipolar and 3 cups] and one case of osteolysis). Overall survival, taking into account revision for aseptic loosening, was 87.6% (CI 95% = 77.3 to 99.3%). The mean PMA and Oxford scores at the final follow-up were 17.6 ± 0.8 points (16–18) and 16.5 ± 5.2 points (12–38) respectively. The radiological follow-up mainly identified radiolucencies around the stem in Gruen zones 1 and 7 (17 and 21% respectively).DiscussionThe survival rate of hybrid MoM THA in this series decreased after 10 years and is lower than studies evaluating cementless THA with the 28-mm Metasul™ bearings (90.9 to 100% survival). Although the clinical results are satisfactory, survival is lower. However, the role of MoM bearings is relative in these failures, in particular because trunnionoses (stainless steel stem with 28-mm head), impingement and especially 5-stem fractures were the main causes of failure.Level of evidenceIV: retrospective study.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Orthopaedics & Traumatology: Surgery & Research - Volume 101, Issue 8, December 2015, Pages 929–936
نویسندگان
, , , , ,