کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4081210 1267583 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Short-segment posterior instrumentation combined with calcium sulfate cement vertebroplasty for thoracolumbar compression fractures: Radiographic outcomes including nonunion and other complications
ترجمه فارسی عنوان
ابزار قطعی خلفی همراه با استراب پلاستیسیته کلسیم سولفات سیمان برای شکستگی فشاری توراکولومار: نتایج رادیوگرافی از جمله عدم ارتباط و سایر عوارض
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

ObjectiveTo evaluate the radiographic outcomes of short-segment posterior instrumentation plus vertebroplasty using injectable calcium sulfate cement (CSC) for thoracolumbar compression fractures.Materials and methodsTwenty-eight patients with a single-level thoracolumbar compression fracture, who underwent short-segment pedicle screw fixation and CSC vertebroplasty, were included in the study. The anterior vertebral body height ratio, local kyphosis angle, and the height of the intervertebral disc adjacent to the fractured vertebra were used to evaluate the radiographic results. Complications including bone nonunion, instrument failure, cement leakage, and disc vacuum formation were also assessed.ResultsThe patients were followed up for an average of 24.20 ± 5.40 months. The relative preoperative anterior body height was 55.71 ± 15.29%, which improved to 94.93 ± 5.39% immediately after surgery (P < 0.001), and at final follow-up showed a 6.50 ± 3.89% loss of height correction (P < 0.001). The mean preoperative local kyphosis angle was 22.23 ± 5.65°, which corrected to 2.67 ± 4.43° immediately after surgery (P < 0.001), but reverted to 6.71 ± 4.95° at final follow-up, showing a 4.04 ± 1.91° loss of correction (P < 0.001). The mean height of the intervertebral disc proximal to the fractured vertebra was 9.87 ± 0.91 mm before surgery, 12.53 ± 0.98 mm after operation (P < 0.001), and the loss of correction at final follow-up was 2.35 ± 1.15 mm with a significant difference compared to immediate postoperative values (P < 0.001). Bone nonunion occurred in 7 patients, 2 patients had hardware failure, 9 patients had cement leakage, and 10 patients had disc vacuum phenomenon adjacent to the fractured vertebra.ConclusionsThe patients who underwent this procedure had a loss of correction of vertebral height and local kyphosis. Complications such as bone nonunion, instrument failure, cement leakage, and disc vacuum may occur. Rapid CSC resorption accounts for these radiographic outcomes and complications.Level of evidenceLevel IV, retrospective study.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Orthopaedics & Traumatology: Surgery & Research - Volume 101, Issue 2, April 2015, Pages 227–233
نویسندگان
, , , , ,