کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4081908 1267614 2011 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Components anteversion in primary cementless THA using straight stem and hemispherical cup: A prospective study in 91 hips using CT-scan measurements
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Components anteversion in primary cementless THA using straight stem and hemispherical cup: A prospective study in 91 hips using CT-scan measurements
چکیده انگلیسی

SummaryBackgroundThe recommended range of anteversion of the components in total hip arthroplasty (THA) is between 10 and 30°, but the intraoperative estimation of these versions may be inadequate.HypothesisThe components anteversion in primary cementless THA using straight stem and hemispherical cup is not significantly different from the native anteversion of the hip joint.ObjectivesTo evaluate in a prospective manner the range of anteversion currently achieved in cementless THA.Patients and methodsFive senior surgeons operated 91 patients with primary cementless THA. We used a straight press fit stem and a hemispherical press fit cup. We aimed to obtain femoral anteversion of 10 to 30°, acetabular anteversion of 10 to 30° and a global combined anteversion of 25 to 55°. Cup position was checked with an impactor-positioner, and stem position was determined with the knee flexed 90°. In all cases we used elevated liners and 28 mm diameter ceramic heads. At 3 months postoperatively the component versions were measured using a General Electric LightSpeed Pro 16 (Milwaukee, Wi, USA) with the patient in supine position.ResultsFemoral component measurements ranged from 17° of retroversion to 60° of anteversion with a mean of 23.0 ± 11.8°. Similarly, acetabular component version ranged from 28° of retroversion to 46° of anteversion with a mean of 18.5 ± 13.7°. There were no correlations to the native femoral and acetabular versions. Only 55 hips (60.4%) were within the accepted range of 25 to 55° of combined anteversion, but none of the cases dislocated during a follow-up of 2 years.ConclusionIn cementless THA with our operative technique, the intraoperative estimation of femoral and acetabular anteversion, in many cases, resulted to be inadequate in relation to the intended range of 10 to 30° of anteversion.Level of evidenceLevel III, prospective diagnostic.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Orthopaedics & Traumatology: Surgery & Research - Volume 97, Issue 6, October 2011, Pages 615–621
نویسندگان
, ,