کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4082005 1267619 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Rotational positioning of the tibial tray in total knee arthroplasty: A CT evaluation
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Rotational positioning of the tibial tray in total knee arthroplasty: A CT evaluation
چکیده انگلیسی

SummaryIntroductionVarious surgical techniques have been described to set the rotational alignment of the tibial baseplate during total knee arthroplasty. The self-positioning method (“self-adjustment”) aligns the tibial implant according to the rotational alignment of the femoral component which is used as a reference after performing repeated knee flexion/extension cycles. Postoperative computed tomography scanning produces accurate measurements of the tibial baseplate rotational alignment with respect to the femoral component.HypothesisThe rotational positioning of the tibial baseplate matches the rotation of the femoral component with parallel alignment to the prosthetic posterior bicondylar axis.Patients and methodsA 3-month follow-up CT scan was carried out after primary total knee arthroplasty implanted in osteoarthritic patients with a mean 7.8° varus deformity of the knee in 50 cases and a mean 8.7° valgus deformity of the knee in 44 cases. The NexGen LPS Flex (Zimmer) fixed-bearing knee prosthesis was used in all cases. An independant examiner (not part of the operating team) measured different variables: the angle between the anatomic transepicondylar axis and the posterior bicondylar axis of the femoral prosthesis (prosthetic posterior condylar angle), the angle between the posterior bicondylar axis and the posterior marginal axis of the tibial prosthesis, the angle between the posterior marginal axis of the tibial prosthesis and the posterior marginal axis of the tibial bone and finally the angle between the anatomic transepicondylar axis and the posterior marginal axis of the tibial prosthesis.ResultsFor the genu varum and genu valgum subgroups, the mean posterior condylar axis of the femoral prosthesis was 3.1° (SD: 1.91; extremes 0° to 17.5°) and 4.7° (SD: 2.7; extremes 0° to 11°) respectively. The tibial baseplate was placed in external rotation with respect to the femoral component: 0.7° (SD : 4.45; extremes –9.5° to 9.8°) and 0.9° (SD: 4.53; extremes –10.8° to 9.5°), but also to the native tibia: 6.1° (SD: 5.85; extremes –4.6° to 22.5°) and 12.5° (SD: 8.6; extremes –10° to 28.9°). The tibial component was placed in internal rotation relative to the anatomic transepicondylar axis: 1.9° (SD : 4.93; extremes –13.6° to 7°) and 3° (SD : 4.38; extremes –16.2° to 4.8°).DiscussionThe tibial component is aligned parallel to the femoral component whatever the initial frontal deformity (P ≅ 0.7). However, a difference was observed between the rotational alignment of the tibial baseplate and the native tibia depending on the initial deformity and could be attributed to the morphological variations of the bony tibial plateau in case of genu valgum.ConclusionThe self-positioning method is a reproducible option when using this type of implant since it allows the tibial component to be positioned parallel to the posterior border of the femur.Level of evidenceLevel III. Observational prospective study.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Orthopaedics & Traumatology: Surgery & Research - Volume 97, Issue 7, November 2011, Pages 699–704
نویسندگان
, , , , ,