کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4155163 1273737 2015 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Improving central line infection rates in the neonatal intensive care unit: Effect of hospital location, site of insertion, and implementation of catheter-associated bloodstream infection protocols
ترجمه فارسی عنوان
بهبود میزان عفونت خطی مرکزی در بخش مراقبت های ویژه نوزادان: تأثیر محل بیمارستان، محل تزریق و اجرای پروتکل های آلودگی خون در ارتباط با کاتتر
کلمات کلیدی
عفونت های جریان خون وابسته به کاتتر، بسته نرم افزاری، کاتتر وریدی مرکزی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پریناتولوژی (پزشکی مادر و جنین)، طب اطفال و بهداشت کودک
چکیده انگلیسی

IntroductionCatheter associated blood stream infections (CABSIs) are morbid and expensive for all ages, including neonates. Thus far, the impact of CABSI prevention protocols, such as insertion and maintenance bundles, in the neonatal intensive care unit (NICU) is largely unknown. We hypothesized that lines placed in the operating room (OR) would have a lower infection rate due to established insertion protocols and a more sterile environment.MethodsA retrospective chart review of NICU patients who received a percutaneous or tunneled central venous catheter between 2005 and 2012 was performed. ECMO cannulas, PICC and umbilical catheters were excluded. Variables of interest included demographics, anatomical site, hospital location, line days, and line infection. Line infection was defined as a positive blood culture drawn through the catheter.ResultsA total of 368 catheters were placed in 285 NICU patients. Majority of catheters (65.5%) were placed in OR. Saphenous and femoral veins were most common anatomical sites (50.8%). Twenty-eight catheters were infected (7.6%). After adjusting for preoperative antibiotics, anatomical site, and SNAPPE-II scores, lines placed in OR were three times less likely to become infected (Odds Ratio = 0.32, p = 0.038). Although implementation of CABSI prevention protocols resulted in statistically significant reductions in infection (Odds Ratio = 0.4, p = 0.043), lines placed in the OR remained less likely to become infected.ConclusionsNICU line infection rates decreased with implementation of CABSI prevention protocols. Despite this implementation, catheters placed in the NICU continued to have higher infection rates. As a result, when patient status allows it, we recommend that central lines in newborns be placed in the operating room.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pediatric Surgery - Volume 50, Issue 5, May 2015, Pages 860–863
نویسندگان
, , , , ,