کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4255961 1284506 2016 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Accuracy and Trending of Continuous Noninvasive Hemoglobin Monitoring in Patients Undergoing Liver Transplantation
ترجمه فارسی عنوان
دقت و سهولت در نظارت بر هموگلوبین غیرمهاجم مداوم در بیماران تحت پیوند کبد
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
چکیده انگلیسی


• The study describes application of noninvasive hemoglobin monitoring in liver transplantation.
• A moderate correlation between CO oximetry and blood gas analyzer measurements was found.
• The Pulse CO-Oximetry was not reliable to monitor hemoglobin levels and trends.
• Critical physical status and low arterial hemoglobin levels lead to larger bias.

BackgroundShift in large fluid volumes and massive blood loss during liver transplantation frequently leads to rapid changes in hemoglobin (Hb) concentration; thus, to ensure adequate tissue oxygenation, accurate and rapid determination of Hb concentration is essential in transplant recipients. The Radical-7 Pulse CO-Oximeter provides a noninvasive and continuous way to monitor Hb concentration (SpHb) in real time and is an ideal candidate for use during liver transplantation. In this study, we assessed the relationship between SpHb and total Hb (tHb) obtained from arterial blood samples during surgery.MethodsForty patients undergoing liver transplantation were enrolled in this study. tHb and time-matched SpHb were measured at 5 different phases throughout surgery. Paired SpHb and tHb levels were assessed using linear regression, Bland-Altman analysis, and the Critchley polar plot method.ResultsA total of 161 paired measurements with sufficient signal quality were analyzed. The correlation between SpHb and tHb was 0.59 (P < .001). Bland-Altman analysis revealed that a bias between SpHb and tHb was 2.28 g/dL, and limits of agreement (LoA) were from −0.78 to 5.34 g/dL. Trending analysis showed that 87% of data were located within the acceptable trending area, indicating that the trending ability was not satisfied.ConclusionsThe Radical-7 Pulse CO-Oximeter was not sufficient to monitor Hb levels and trends during liver transplantation surgery in our cohort. In particular, in critical patients and in those with low Hb levels, invasive Hb measurement should be used for assessment.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Transplantation Proceedings - Volume 48, Issue 4, May 2016, Pages 1067–1070
نویسندگان
, , , , , , , , ,