Semi-automatic segmentation for prostate interventions
چکیده انگلیسی

In this paper we report and characterize a semi-automatic prostate segmentation method for prostate brachytherapy. Based on anatomical evidence and requirements of the treatment procedure, a warped and tapered ellipsoid was found suitable as the a-priori 3D shape of the prostate. By transforming the acquired endorectal transverse images of the prostate into ellipses, the shape fitting problem was cast into a convex problem which can be solved efficiently.The average whole gland error between non-overlapping volumes created from manual and semi-automatic contours from 21 patients was 6.63 ± 0.9%. For use in brachytherapy treatment planning, the resulting contours were modified, if deemed necessary, by radiation oncologists prior to treatment. The average whole gland volume error between the volumes computed from semi-automatic contours and those computed from modified contours, from 40 patients, was 5.82 ± 4.15%. The amount of bias in the physicians’ delineations when given an initial semi-automatic contour was measured by comparing the volume error between 10 prostate volumes computed from manual contours with those of modified contours. This error was found to be 7.25 ± 0.39% for the whole gland. Automatic contouring reduced subjectivity, as evidenced by a decrease in segmentation inter- and intra-observer variability from 4.65% and 5.95% for manual segmentation to 3.04% and 3.48% for semi-automatic segmentation, respectively. We characterized the performance of the method relative to the reference obtained from manual segmentation by using a novel approach that divides the prostate region into nine sectors. We analyzed each sector independently as the requirements for segmentation accuracy depend on which region of the prostate is considered.The measured segmentation time is 14 ± 1 s with an additional 32 ± 14 s for initialization. By assuming 1–3 min for modification of the contours, if necessary, a total segmentation time of less than 4 min is required, with no additional time required prior to treatment planning. This compares favorably to the 5–15 min manual segmentation time required for experienced individuals. The method is currently used at the British Columbia Cancer Agency (BCCA) Vancouver Cancer Centre as part of the standard treatment routine in low dose rate prostate brachytherapy and is found to be a fast, consistent and accurate tool for the delineation of the prostate gland in ultrasound images.

Figure optionsDownload high-quality image (145 K)Download as PowerPoint slideResearch highlights
► 3D tapered-ellipsoid-guided prostate segmentation produces reliable contours.
► The method uses only a few initialization points in the mid-gland and is fast.
► The method reduces inter/intra-observer variability relative to the manual case.
► Validated on 40 patients, the method is used routinely with 600+ patients to date.