کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
444047 692862 2014 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An implicit sliding-motion preserving regularisation via bilateral filtering for deformable image registration
ترجمه فارسی عنوان
ثابت کردن ثابت نگه داشتن حرکت کششی از طریق فیلتر دو جانبه برای ثبت نام تصویر قابل تنظیم
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر گرافیک کامپیوتری و طراحی به کمک کامپیوتر
چکیده انگلیسی


• Automated registration framework for lung motion estimation.
• Integration of bilateral filters to regularise estimated deformation fields.
• Registration is applied to CT lung data.

Several biomedical applications require accurate image registration that can cope effectively with complex organ deformations. This paper addresses this problem by introducing a generic deformable registration algorithm with a new regularization scheme, which is performed through bilateral filtering of the deformation field. The proposed approach is primarily designed to handle smooth deformations both between and within body structures, and also more challenging deformation discontinuities exhibited by sliding organs. The conventional Gaussian smoothing of deformation fields is replaced by a bilateral filtering procedure, which compromises between the spatial smoothness and local intensity similarity kernels, and is further supported by a deformation field similarity kernel. Moreover, the presented framework does not require any explicit prior knowledge about the organ motion properties (e.g. segmentation) and therefore forms a fully automated registration technique. Validation was performed using synthetic phantom data and publicly available clinical 4D CT lung data sets. In both cases, the quantitative analysis shows improved accuracy when compared to conventional Gaussian smoothing. In addition, we provide experimental evidence that masking the lungs in order to avoid the problem of sliding motion during registration performs similarly in terms of the target registration error when compared to the proposed approach, however it requires accurate lung segmentation. Finally, quantification of the level and location of detected sliding motion yields visually plausible results by demonstrating noticeable sliding at the pleural cavity boundaries.

Figure optionsDownload high-quality image (436 K)Download as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Image Analysis - Volume 18, Issue 8, December 2014, Pages 1299–1311
نویسندگان
, , , , ,