کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
445172 693149 2012 23 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Feature-based interpolation of diffusion tensor fields and application to human cardiac DT-MRI
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر گرافیک کامپیوتری و طراحی به کمک کامپیوتر
پیش نمایش صفحه اول مقاله
Feature-based interpolation of diffusion tensor fields and application to human cardiac DT-MRI
چکیده انگلیسی

Diffusion tensor interpolation is an important issue in the application of diffusion tensor magnetic resonance imaging (DT-MRI) to the human heart, all the more as the points representing the myocardium of the heart are often sparse. We propose a feature-based interpolation framework for the tensor fields from cardiac DT-MRI, by taking into account inherent relationships between tensor components. In this framework, the interpolation consists in representing a diffusion tensor in terms of two tensor features, eigenvalues and orientation, interpolating the Euler angles or the quaternion relative to tensor orientation and the logarithmically transformed eigenvalues, and reconstructing the tensor to be interpolated from the interpolated eigenvalues and tensor orientations. The results obtained with the aid of both synthetic and real cardiac DT-MRI data demonstrate that the feature-based schemes based on Euler angles or quaternions not only maintain the advantages of Log-Euclidean and Riemannian interpolation as for preserving the tensor’s symmetric positive-definiteness and the monotonic determinant variation, but also preserve, at the same time, the monotonicity of fractional anisotropy (FA) and mean diffusivity (MD) values, which is not the case with Euclidean, Cholesky and Log-Euclidean methods. As a result, both interpolation schemes remove the phenomenon of FA collapse, and consequently avoid introducing artificial fiber crossing, with the difference that the quaternion is independent of coordinate system while Euler angles have the property of being more suitable for sophisticated interpolations.

Red circled tensors are original tensors before interpolation, the color of a tensor represent its principal eigenvector orientation.Figure optionsDownload high-quality image (218 K)Download as PowerPoint slideHighlights
► A novel method for diffusion tensor interpolation.
► A diffusion tensor is represented by tensor eigenvalues and tensor orientation.
► Eliminate swelling effect, preserve simultaneously the monotonicity of FA and MD.
► No artificial crossing fibers introduced.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Image Analysis - Volume 16, Issue 2, February 2012, Pages 459–481
نویسندگان
, , , , , ,