Features-clustering-based earth fault detection using singular-value decomposition and fuzzy c-means in resonant grounding distribution systems
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر هوش مصنوعی
پیش نمایش صفحه اول مقاله
Features-clustering-based earth fault detection using singular-value decomposition and fuzzy c-means in resonant grounding distribution systems
چکیده انگلیسی


- Proposing a novel method to detect the earth fault in resonant grounding systems.
- Amplitude and polarity feature matrixes calculating algorithm has been developed.
- Fuzzy c-means clustering is used to replace a threshold setting.
- The proposed method is extensively tested on PSCAD/EMTDC and physical systems.

The transient zero-sequence current of each feeder in a resonant grounding system is characterized by nonlinearity and nonstationarity when a single-phase-to-ground fault occurs. Because there is a significant difference between the fault transient zero-sequence current waveforms of the fault feeder and the sound feeders, a new fault feeder detection method is presented, based on a time-frequency matrix (TFM) and polarity distribution matrix (PDM) singular values clustering algorithm. By applying a Hilbert-Huang transform band-pass filter and waveform transformation to the transient zero-sequence current waveform of each feeder, the TFM and PDM can be constructed, which are decomposed by singular-value decomposition (SVD). Moreover, the normalized singular values of the TFM and PDM are merged together and are used to form the amplitude-polarity feature matrix (APFM). Thus, the feature quantities including the amplitude and polarity information of each fault transient zero-sequence current waveform are obtained. Then, fuzzy c-means clustering is applied to the APFM so as to detect the fault feeder by dividing the fault feeder and sound feeders into two categories without a certain threshold setting. Simulations were carried out via PACAD/EMTDC® and a physical system under various kinds of fault conditions and factors including asynchronous sample, two-point-grounding fault, and arc fault. Simulated results show that the proposed method has the characteristics of high accuracy and reliability in earth fault feeder detection.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Electrical Power & Energy Systems - Volume 93, December 2017, Pages 97-108