کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5004556 | 1461197 | 2015 | 9 صفحه PDF | دانلود رایگان |
- Method for calibration of electrical energy meter.
- Partial automatization of this method.
- Method is used on example of a real electrical energy measurement system.
- Experimental results.
This paper presents the problems of implementation and adjustment (calibration) of a metrology engine embedded in NXP's EM773 series microcontroller. The metrology engine is used in a smart metering application to collect data about energy utilization and is controlled with the use of metrology engine adjustment (calibration) parameters. The aim of this research is to develop a method which would enable the operators to find and verify the optimum parameters which would ensure the best possible accuracy. Properly adjusted (calibrated) metrology engines can then be used as a base for variety of products used in smart and intelligent environments. This paper focuses on the problems encountered in the development, partial automatisation, implementation and verification of this method.
Journal: ISA Transactions - Volume 58, September 2015, Pages 380-388