کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5020430 1469071 2017 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The micro-damage process zone during transverse cortical bone fracture: No ears at crack growth initiation
ترجمه فارسی عنوان
منطقه فرایند آسیب های میکروی در هنگام شکستگی استخوان کورتکس عرضی: بدون ایجاد گوش در هنگام آغاز رشد ترک، گوش فرا می دهد
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی پزشکی
چکیده انگلیسی


- The micro-damage process zone of cortical bone transverse fracture was imaged.
- Imaging was enabled by high-resolution micro-CT with barium sulfate contrast.
- The method allowed for detailed process zone size and shape characterization.
- Process zone growth was compared to various models (analytical, finite element).
- A new mechanism of interaction with the microstructure, termed “flames”, is shown.

ObjectiveApply high-resolution benchtop micro-computed tomography (micro-CT) to gain greater understanding and knowledge of the formation of the micro-damage process zone formed during traverse fracture of cortical bone.MethodsBovine cortical bone was cut into single edge notch (bending) fracture testing specimens with the crack on the transverse plane and oriented to grow in the circumferential direction. We used a multi-specimen technique and deformed the specimens to various individual secant modulus loss levels (P-values) up to and including maximum load (Pmax). Next, the specimens were infiltrated with a BaSO4 precipitation stain and scanned at 3.57-μm isotropic voxel size using a benchtop high resolution-micro-CT. Measurements of the micro-damage process zone volume, width and height were made. These were compared with the simple Irwin's process zone model and with finite element models. Electron and confocal microscopy confirmed the formation of BaSO4 precipitate in micro-cracks and other porosity, and an interesting novel mechanism similar to tunneling.ResultsMeasurable micro-damage was detected at low P values and the volume of the process zone increased according to a second order polynomial trend. Both width and height grew linearly up to Pmax, at which point the process zone cross-section (perpendicular to the plane of the crack) was almost circular on average with a radius of approximately 550 µm (approximately one quarter of the unbroken ligament thickness) and corresponding to the shape expected for a biological composite under plane stress conditions.ConclusionThis study reports details of the micro-damage fracture process zone previously unreported for cortical bone. High-resolution micro-CT enables 3D visualization and measurement of the process zone and confirmation that the crack front edge and process zone are affected by microstructure. It is clear that the process zone for the specimens studied grows to be meaningfully large, confirming the need for the J-integral approach and it does not achieve steady state at Pmax in most specimens. With further development, this approach may become valuable towards better understanding the role of the process zone in cortical bone fracture and the effects of relevant modifications towards changes in fracture toughness in a cost effective way.

205

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the Mechanical Behavior of Biomedical Materials - Volume 74, October 2017, Pages 371-382
نویسندگان
, , , , ,