کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5477396 1521525 2017 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance analysis of a 11.2 kWp roof top grid-connected PV system in Eastern India
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Performance analysis of a 11.2 kWp roof top grid-connected PV system in Eastern India
چکیده انگلیسی
Barren land and roof tops of buildings are being increasingly used worldwide to install solar panels for generating electricity. One such step has been taken by Siksha 'O'Anusandhan University, Bhubaneswar (Latitude 20.24° N and Longitude 80.85° E) by installing a 11.2 kWp grid connected solar power system during February, 2014. This PV system is tilted at an angle of 21° on the top floor of a 25 metre height building. This system was installed This paper presents the results of this grid connected photovoltaic system which was monitored between September 2014 to August 2015. The entire electricity generated by the system was fed into the state grid. The different parameters of the system studied include PV module efficiency, array yield, final yield, inverter efficiency and performance ratio of the system. The total energy generated during this period was found to be 14.960 MWh and the PV module efficiency, inverter efficiency and performance ratio were found to be 13.42%, 89.83% and 0.78 respectively.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy Reports - Volume 3, November 2017, Pages 76-84
نویسندگان
, ,