The main objective of this work was to characterize the new multi-pixel photon counter (MPPC) arrays with a 12Ã12mm2 and a 24Ã24mm2 active area, made using through-silicon via (TSV) technology and with trenches introduced between the cells, in gamma-ray spectrometry with five different scintillators: CsI:Tl, NaI:Tl, LSO/LYSO, BGO, and LaBr3. The results of the study are compared to those obtained previously with the older sample of the 12Ã12mm2 MPPC array made as a monolithic device. TSV MPPC array with the size of 24Ã24mm2 is one of the first commercially available SiPM with such a large active area and with the dead space between channels minimized to only 0.2 mm. Moreover, in these devices, Hamamatsu introduced trenches between cells to reduce cross-talk. Hence excess noise factor (ENF) was also reduced from a value of 1.7 to 1.2 in comparison to the “old” monolithic sample (data for the same overvoltage of 1.3V). Whereby for the new MPPCs, the optimum operating voltage is higher by about 0.6V. In consequence, this higher optimal overvoltage means a higher photon detection efficiency (PDE) and number of photoelectrons, and leads to improved energy resolution. Energy resolution measured for the 662keV full energy peak in a 137Csγ-source spectrum recorded with 12Ã12mm2 TSV MPPC and two CsI:Tl scintillators (12Ã12Ã12mm3 and 1Ã1in) equals to 5.8% and 6.8%, respectively. For the “old” MPPC with the same CsI:Tl scintillators energy resolution is equal to 6.4% and 7.1%, respectively. These improved TSV MPPC arrays can be commercially used for scintillation light readout of “large” crystals with a diameter of 1Ã1in or 2Ã2in, suitable for gamma spectrometry in a wide range of applications. The combination of new 8Ã8ch (24Ã24mm2) TSV MPPC and 2Ã2in NaI:Tl gives an excellent energy resolution below 8%, despite the incomplete match of the scintillator surface to the active area of MPPC and loss of the part of the light.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 869, 11 October 2017, Pages 153-162
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 869, 11 October 2017, Pages 153-162
نویسندگان
M. Grodzicka-Kobylka, T. Szczesniak, M. MoszyÅski, S. Korolczuk, J. Baszak, M. Kapusta,