کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5492816 1526281 2017 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Radiation hardness and precision timing study of silicon detectors for the CMS High Granularity Calorimeter (HGC)
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Radiation hardness and precision timing study of silicon detectors for the CMS High Granularity Calorimeter (HGC)
چکیده انگلیسی
For an integrated luminosity of 3000 fb−1, the electromagnetic calorimetry will sustain integrated doses of 1.5 MGy (150 Mrads) and neutron fluences up to 1016 neq/cm2. A radiation tolerance study after neutron irradiation of 300, 200, and 100 μm n-on-p and p-on-n silicon pads irradiated to fluences up to 1.6×1016 neq/cm2 is presented. The properties of these diodes studied before and after irradiation were leakage current, capacitance, charge collection efficiency, annealing effects and timing capability. The results of these measurements validate these sensors as candidates for the HGC system.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 845, 11 February 2017, Pages 60-63
نویسندگان
, , , , , , , , , , , , ,