کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5529398 1401696 2016 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Deformable image registration between pathological images and MR image via an optical macro image
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی تحقیقات سرطان
پیش نمایش صفحه اول مقاله
Deformable image registration between pathological images and MR image via an optical macro image
چکیده انگلیسی


- We propose a deformable image registration scheme for pathological images and a 3D-MR image.
- An optical macro image is used as mediate image on the image registration.
- Same regions between pathological images and the MR image can be searched and displayed.
- The relationship between tissue information and MR signals of the whole human brain can be analyzed using the proposed method.

Computed tomography (CT) and magnetic resonance (MR) imaging have been widely used for visualizing the inside of the human body. However, in many cases, pathological diagnosis is conducted through a biopsy or resection of an organ to evaluate the condition of tissues as definitive diagnosis. To provide more advanced information onto CT or MR image, it is necessary to reveal the relationship between tissue information and image signals. We propose a registration scheme for a set of PT images of divided specimens and a 3D-MR image by reference to an optical macro image (OM image) captured by an optical camera. We conducted a fundamental study using a resected human brain after the death of a brain cancer patient. We constructed two kinds of registration processes using the OM image as the base for both registrations to make conversion parameters between the PT and MR images. The aligned PT images had shapes similar to the OM image. On the other hand, the extracted cross-sectional MR image was similar to the OM image. From these resultant conversion parameters, the corresponding region on the PT image could be searched and displayed when an arbitrary pixel on the MR image was selected. The relationship between the PT and MR images of the whole brain can be analyzed using the proposed method. We confirmed that same regions between the PT and MR images could be searched and displayed using resultant information obtained by the proposed method. In terms of the accuracy of proposed method, the TREs were 0.56 ± 0.39 mm and 0.87 ± 0.42 mm. We can analyze the relationship between tissue information and MR signals using the proposed method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Pathology - Research and Practice - Volume 212, Issue 10, October 2016, Pages 927-936
نویسندگان
, , , , , , , , , , ,