کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5529990 | 1401711 | 2017 | 6 صفحه PDF | دانلود رایگان |
Background and purposeTo investigate (1) whether a plan library established at one institution can be applied for another institution's knowledge-based planning (KBP); (2) the performance of cross-institutional KBP compared to Auto-Planning Engine (APE).Material and methodsRadboud University Medical Center (RUMC) provided 35 oropharyngeal cancer patients (68 Gy to PTV68 and 50.3 Gy to PTV50.3) with clinically-delivered and comparative APE plans. The Johns Hopkins University (JHU) contributed a three-dose-level plan library consisting of 179 clinically-delivered plans. MedStar Georgetown University Hospital (MGUH) contributed a KBP approach employing overlap-volume histogram (OVH-KBP), where the JHU library was used for guiding RUMC patients' KBP. Since clinical protocols adopted at RUMC and JHU are different and both approaches require protocol-specific planning parameters as initial input, 10 randomly selected patients from RUMC were set aside for deriving them. The finalized parameters were applied to the remaining 25 patients for OVH-KBP and APE plan generation. A Wilcoxon rank-sum test was used for statistical comparison.ResultsPTV68 and PTV50.3's V95 in OVH-KBP and APE were similar (p > 0.36). Cord's D0.1 cc in OVH-KBP was reduced by 5.1 Gy (p = 0.0001); doses to other organs were similar (p > 0.2).ConclusionAPE and OVH-KBP's plan quality is comparable. Institutional-protocol differences can be addressed to allow cross-institutional library sharing.
Journal: Radiotherapy and Oncology - Volume 123, Issue 1, April 2017, Pages 57-62