کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5597366 1573870 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Original articleAdult cardiacTranscatheter Aortic Valve-in-Valve Implantation Using Lotus Valve for Failed Surgical Bioprostheses
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Original articleAdult cardiacTranscatheter Aortic Valve-in-Valve Implantation Using Lotus Valve for Failed Surgical Bioprostheses
چکیده انگلیسی

BackgroundPatients with failed bioprostheses are an increasing population at high risk for redo surgery. Valve-in-valve transcatheter aortic valve implantation is a promising alternative but a limited number of first-generation devices have proven efficacy in all cases.MethodsPatients with degenerated bioprostheses at high risk for redo surgery were included in the registry after being assigned to valve-in-valve intervention by a local heart team. Main basal and follow-up data (at 1 month and 6 months) of patients undergoing valve-in-valve transcatheter aortic valve implantation with the Lotus valve system (Boston Scientific, Natick, MA) in three high-volume Italian centers were entered in the registry.ResultsTwelve patients (aged 71.1 ± 14.1 years, 66% male, logistic European System for Cardiac Operative Risk Evaluation score 28.8 ± 22.9) were included in the registry. Implantation success rate was 92%; in 1 patient, the valve was completely retrieved because of unsatisfactory gradients after valve positioning. All procedures were done through femoral access, and all but one required only local anesthesia. In patients with stenosis as pure or mixed mechanism for degeneration (n = 7), mean ventriculoaortic gradient decreased from 46.7 ± 7.0 mm Hg to 16.6 ± 5.7 mm Hg (p < 0.001). No patients had more than mild aortic regurgitation at hospital discharge. Results where confirmed at 1-month and 6-month follow-up, with improvement of New York Heart Association functional status in all patients (functional class I to II in 100% of patients).ConclusionsThe valve-in-valve procedure using the Lotus valve is a feasible alternative to repeat surgery in high-risk patients with degenerated bioprostheses. Using the Lotus valve in this challenging and increasingly frequent scenario could offer a safe and effective strategy that should be explored in larger clinical trials.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Annals of Thoracic Surgery - Volume 104, Issue 2, August 2017, Pages 638-644
نویسندگان
, , , , , , , , , ,