کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5662928 | 1407597 | 2016 | 9 صفحه PDF | دانلود رایگان |
This preliminary study evaluated the transport reagent OMNIgene SPUTUM (OMS) in a real-world, resource-limited setting: a zonal hospital and national tuberculosis (TB) reference laboratory, Nepal. The objectives were to: (1) assess the performance of OMS for transporting sputum from peripheral sites without cold chain stabilization; and (2) compare with Nepal's standard of care (SOC) for Mycobacterium tuberculosis smear and culture diagnostics. Sixty sputa were manually split into a SOC sample (airline-couriered to the laboratory, conventional processing) and an OMS sample (OMS added at collection, no cold chain transport or processing). Smear microscopy and solid culture were performed. Transport was 0-8Â days. Forty-one samples (68%) were smear-positive using both methods. Of the OMS cultures, 37 (62%) were positive, 22 (36%) were negative, and one (2%) was contaminated. Corresponding SOC results were 32 (53%), 21 (35%), and seven (12%). OMS “rescued” six (i.e., missed using SOC) compared with one rescue using SOC. Of smear-positives, six SOC samples produced contaminated cultures whereas only one OMS sample was contaminated. OMS reduced culture contamination from 12% to 2%, and improved TB detection by 9%. The results suggest that OMS could perform well as a no cold chain, long-term transport solution for smear and culture testing. The findings provide a basis for larger feasibility studies.
Journal: Journal of Epidemiology and Global Health - Volume 6, Issue 4, December 2016, Pages 257-265