کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5722947 1608910 2017 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Sutureless functional end-to-end anastomosis using a linear stapler with polyglycolic acid felt for intestinal anastomoses
ترجمه فارسی عنوان
آناستوموز به پایان رسیده به شانه بدون استفاده از یک استپلر خطی با اسید پلی گلیکولیک برای آناستوموز روده ای
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی سیاست های بهداشت و سلامت عمومی
چکیده انگلیسی


- Functional end-to-end anastomosis is safe with the Endo GIA™ Reinforced stapler.
- Conventional functional end-to-end anastomosis requires suture reinforcement.
- The Endo GIA™ Reinforced allows sutureless anastomosis by creating staple planes.

BackgroundGastrointestinal anastomosis remains associated with a considerable burden of morbidity and, in some cases, mortality. Functional end-to-end anastomosis, whilst extremely efficient, is vulnerable to increased intestinal pressure in the immediate postoperative period, which may predispose to development of anastomotic leakage or bleeding. Therefore, there is a requirement for new techniques that facilitate safe and efficacious anastomotic procedures.Materials and methodsThis study examined the clinical application of functional end-to-end anastomosis with a stapler that automatically applies a bioabsorbable polyglycolic acid sheet (Endo GIA™ Reinforced Reload with Tri-Staple™ Technology). A porcine model was used to examine functional end-to-end anastomosis with and without application of a bioabsorbable polyglycolic acid sheet. As the crotch of the anastomosis is considered the weakest point, a probe was used to test the integrity of these anastomoses. Furthermore, we performed functional end-to-end anastomosis using the Endo GIA™ Reinforced stapler in a clinical series of 20 patients undergoing gastrointestinal tract resection. In all cases, functional end-to-end anastomosis was performed without suture reinforcement.ResultsSmall intestine anastomoses in the animal study exhibited no weakness at the crotch of the anastomosis, as tested with a probe, suggesting an increased resiliency to conventional complications of functional end-to-end anastomosis. In the clinical population, no postoperative complications were noted. No adhesive intestinal obstruction was noted.ConclusionSutureless functional end-to-end anastomosis using the Endo GIA™ Reinforced appears to be safe, efficacious, and straightforward. Reinforcement of the crotch site with a bioabsorbable polyglycolic acid sheet appears to mitigate conventional problems with crotch-site vulnerability.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Annals of Medicine and Surgery - Volume 17, May 2017, Pages 50-53
نویسندگان
, , , , , , , , , , , ,