کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5873217 1144482 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Original ArticleA Systemized Stroke Code Significantly Reduced Time Intervals for Using Intravenous Tissue Plasminogen Activator under Magnetic Resonance Imaging Screening
ترجمه فارسی عنوان
اصل مقاله با سندرم سیتیزنتال، فاصله زمانی معکوس برای استفاده از فعال کننده پلاسمینوژن داخل وریدی با استفاده از تست تصادفی رزونانس مغناطیسی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی مغز و اعصاب بالینی
چکیده انگلیسی

BackgroundA stroke code can shorten time intervals until intravenous tissue plasminogen activator (IV t-PA) treatment in acute ischemic stroke (AIS). Recently, several reports demonstrated that magnetic resonance imaging (MRI)-based thrombolysis had reduced complications and improved outcomes in AIS despite longer processing compared with computed tomography (CT)-based thrombolysis.MethodsIn January 2009, we implemented CODE RED, a computerized stroke code, at our hospital with the aim of achieving rapid stroke assessment and treatment. We included patients with thrombolysis from January 2007 to December 2008 (prestroke code period) and from January 2009 to May 2013 (poststroke code period). The IV t-PA time intervals and 90-day modified Rankin Scale (mRS) scores were collected.ResultsDuring the observation period, 252 patients used IV t-PA under the CODE RED (MRI based: 208; CT based: 44). The remaining 71 patients (MRI based: 53; CT based: 18) received it before the implementation of our stroke code. After implementation of CODE RED, door-to-image time, door-to-needle time, and the onset-to-needle time were significantly reduced by 11, 18, and 22 minutes in MRI-based thrombolysis. Particularly, the proportion of favorable outcome (mRS score 0-2) was significantly increased (from 41.5% to 60.1%, P = .02) in poststroke than in prestroke code period in MRI-based thrombolysis. However, in ordinal regression, the presence of stroke code showed just a trend for favorable outcome (odds ratio, .99-2.87; P = .059) at 90 days of using IV t-PA after correction of age, sex, and National Institutes of Health Stroke Scale.ConclusionsIn this study, we demonstrated that a systemized stroke code shortened time intervals for using IV t-PA under MRI screening. Also, our results showed a possibility that a systemized stroke code might enhance the efficacy of MRI-based thrombolysis. In the future, we need to carry out a more detailed prospective study about this notion.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Stroke and Cerebrovascular Diseases - Volume 24, Issue 2, February 2015, Pages 465-472
نویسندگان
, , , , , , , , , , , , ,