کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5923658 1571175 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of two isometric handgrip protocols on sympathetic arousal in women
ترجمه فارسی عنوان
مقایسه دو پروتکل دسته بندی ایزومتری بر تحریک سمپاتی در زنان
کلمات کلیدی
دستگیره، تحریک سمپاتیک، نوراپی نفرین، انعقاد دانش آموز، زنان،
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی فیزیولوژی
چکیده انگلیسی


- Isometric handgrip is used in stress research because it increases arousal.
- We tested if two different handgrip tasks elicited similar arousal changes.
- Pupil dilation increased significantly to handgrip only in the 18-s protocol.
- The 18-s paradigm should induce arousal, regardless of experiment parameters.

Isometric handgrip is commonly used in stress research because the task reliably increases sympathetic arousal. Various handgrip protocols have been used; they vary in handgrip strength, duration of grip, and the number of cycles of handgrip and rest. However, most protocols require the calibration of a maximum voluntary contraction (MVC) prior to the handgrip task, which is not always convenient (i.e., in a functional magnetic resonance imaging study). Here, we wanted to test whether two handgrip protocols with different strength, duration and cycle protocols would reliably elicit sympathetic arousal in the absence of calibrating an MVC. Sixty-two healthy naturally cycling women and women on hormonal contraception participated in one of the two isometric handgrip protocols using a hand therapy ball of medium resistance. Women completed one of the following handgrip protocols: 1) 30% of a perceived maximum voluntary contraction for 3 min or 2) 3 cycles of maximum voluntary contraction for 18 s with a one minute rest in between. All handgrip blocks were counterbalanced with a control condition. Sympathetic arousal was measured throughout the session via pupil diameter changes and salivary alpha-amylase. Results indicate that in the absence of calibrating an MVC, the handgrip tasks elicited different changes in sympathetic arousal. Pupil dilation responses increased significantly in the handgrip versus control blocks only in participants in the 18-s protocol. Additionally, more participants exhibited a salivary alpha-amylase response to the handgrip block in the 18-s condition compared to the 3-min condition. Thus, these results suggest that neuroimaging and behavioral studies with isometric handgrip should be able to successfully induce sympathetic nervous activity with the 18-s paradigm, regardless of the handgrip device and the ability to calibrate an MVC.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Physiology & Behavior - Volume 142, 1 April 2015, Pages 5-13
نویسندگان
, ,