کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5958102 1575444 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Three-Dimensional Ultrasound Evaluation of Small Asymptomatic Abdominal Aortic Aneurysms
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Three-Dimensional Ultrasound Evaluation of Small Asymptomatic Abdominal Aortic Aneurysms
چکیده انگلیسی

ObjectiveNon-invasive and reproducible size measurements that correlate well with computed tomography (CT) are desirable in the management of small abdominal aortic aneurysms (AAA). Three dimensional ultrasound (3D-US) technology may reduce inaccuracy because of variations in orientation of the image planes and axis. This study aimed to determine any differences in paired size estimation associated with three 3D-US derived methods using 3D-CT as the gold standard. When CTA was not available, the patients were enrolled anyway to assess 3D-US reproducibility in terms of agreement between two physicians.MethodsIn the period from 1 March 2013 to 27 February 2014, consecutive patients with a small AAA, <5.5 cm for men and <5.2 cm for women, underwent 3D-US examination and three AAA size measures were obtained: dual plane diameter, diameter perpendicular to the residual sac's centreline and a partial volume.ResultIn all, 122 consecutive US examinations were performed. Patients were excluded because of inadequate AAA size (n = 11) and for technical reasons (n = 11). Thus, 100 patients (F/M; 20/80) with a median maximum AAA diameter of 46 (range 31-55) mm were analysed. The mean US dual plane diameter and the 3D-US centreline diameter were 2.6 mm and 1.8 mm smaller than the mean 3D-CT centreline diameter, respectively (p = .003). The inter-observer reproducibility coefficient was 3.7 mm for the US dual plane diameter and 3.2 mm for the 3D-US centreline diameter (p = 0.222). For the partial volume, the reproducibility was 8-12%, corresponding to a diameter variability of ±3 mm. The median time used for post-processing of the 3D-US acquisition was 72 (range 46-108) seconds per examination.Conclusion3D-US demonstrated an acceptable reproducibility and a good agreement with 3D-CT, and has the potential to improve future AAA management through more reliable ultrasound guided size estimates.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Vascular and Endovascular Surgery - Volume 49, Issue 3, March 2015, Pages 289-296
نویسندگان
, , , , , , ,