کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5990988 1578623 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Use of continuous flow ventricular assist devices in patients with heart failure and a normal ejection fraction: A computer-simulation study
ترجمه فارسی عنوان
استفاده از دستگاه های کمک بطنی بطری مداوم در بیماران مبتلا به نارسایی قلبی و کسر تخلیه طبیعی: یک مطالعه شبیه سازی کامپیوتری
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی

ObjectivesContinuous flow left ventricular assist devices are used in end-stage systolic heart failure. However, about one half of the patients with heart failure exhibit diastolic dysfunction with a normal ejection fraction. In the present study, the possible hemodynamic consequences of continuous flow left ventricular assist devices use for these patients were investigated.MethodsA previously developed cardiovascular model was modified to reproduce the peculiar hemodynamics of heart failure with a normal ejection fraction. The model was based on and validated with patient data derived from the published data. A continuous flow left ventricular assist device model was included and the hemodynamic effects of pump support evaluated at rest and during exercise.ResultsThe model accurately reproduced the published data both at rest and during exercise, leading to simulated hemodynamic values within the standard deviations of patient variability. At rest, pump support decreased the end-diastolic left ventricular pressure (6 vs 15 mm Hg) and volume (88 vs 135 mL). During exercise, maximal pump support substantially unloaded the left ventricle (end-diastolic pressure, 14 vs 35 mm Hg; volume, 133 vs 158 mL) and the pulmonary venous circulation (left atrial pressure, 12 vs 24 mm Hg) and resulted in a slight increase in cardiac output (11.7 vs 9.9 L/min).ConclusionsThe simulation results suggested that continuous flow left ventricular assist devices improve the hemodynamics in patients with heart failure and a normal ejection fraction. For an optimal use of continuous flow left ventricular assist devices, low speeds should be maintained at rest, to avoid suction. However, during physical activity, higher speeds are needed to prevent an abnormal increase in the ventricular filling pressures typical of patients with heart failure and a normal ejection fraction.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 145, Issue 5, May 2013, Pages 1352-1358
نویسندگان
, , , , , ,