کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5994306 1179828 2014 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Anatomic feasibility of off-the-shelf fenestrated stent grafts to treat juxtarenal and pararenal abdominal aortic aneurysms
ترجمه فارسی عنوان
امکان سنجی آناتومیکی از گرافت های استنته خارج از قفسه سینه برای درمان آنوریسم آئورت شکمی و پارارنال
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی

ObjectiveThe objective of this study was to evaluate the anatomic feasibility of two off-the-shelf fenestrated stent graft designs to treat juxtarenal and pararenal abdominal aortic aneurysms (AAAs).MethodsDigital computed tomography angiograms were analyzed in 520 consecutive patients treated by open or fenestrated endovascular repair for complex AAAs (2000-2012). The anatomic feasibility of two off-the-shelf fenestrated designs, Endologix Ventana (Endologix Inc, Irvine, Calif) and Cook p-Branch (Cook Medical, Brisbane, Australia), was analyzed with the instructions for use (IFU) proposed by investigational protocols.ResultsThere were 390 patients (75%) with juxtarenal and pararenal AAAs considered potential candidates for one of the two devices. Proximal seal (>15 mm) was achieved in all patients with the p-Branch and in 61% of the patients with the Ventana stent graft (P < .0001). The ability to incorporate visceral arteries was greater with the Ventana (90% vs 61%) compared with the p-Branch design (P < .0001). Less than a third of patients met strict IFU criteria with Ventana (27%) or p-Branch (33%; P < .05). By liberal IFU criteria, 42% of patients were candidates for Ventana and 49% for p-Branch (P < .03). Overall, 63% of the patients with juxtarenal and pararenal AAAs were candidates for endovascular repair with one of the two devices.ConclusionsThe p-Branch design has greater anatomic feasibility and achieves proximal seal in all patients with juxtarenal and pararenal AAAs but is not able to incorporate visceral arteries in 40% of patients. The Ventana design allows incorporation of the visceral arteries in 90% of patients but fails to provide sufficient seal in 40%. Nearly 40% of juxtarenal and pararenal AAAs do not meet anatomic criteria for endovascular repair with one of the two devices, justifying the need for additional designs.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Vascular Surgery - Volume 60, Issue 4, October 2014, Pages 839-848.e2
نویسندگان
, , , , , , , ,