کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5994579 1179830 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Dutch experience with the fenestrated Anaconda endograft for short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Dutch experience with the fenestrated Anaconda endograft for short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair
چکیده انگلیسی

ObjectiveIn the past decennium, the management of short-neck infrarenal and juxtarenal aortic aneurysms with fenestrated endovascular aneurysm repair (FEVAR) has been shown to be successful, with good early and midterm results. Recently, a new fenestrated device, the fenestrated Anaconda (Vascutek, Renfrewshire, Scotland), was introduced. The aim of this study was to present the current Dutch experience with this device.MethodsA prospectively held database of patients treated with the fenestrated Anaconda endograft was analyzed. Decision to treat was based on current international guidelines. Indications for FEVAR included an abdominal aortic aneurysm (AAA) with unsuitable neck anatomy for EVAR. Planning was performed on computed tomography angiography images using a three-dimensional workstation.ResultsBetween May 2011 and September 2013, 25 patients were treated in eight institutions for juxtarenal (n = 23) and short-neck AAA (n = 2). Median AAA size was 61 mm (59-68.5 mm). All procedures except one were performed with bifurcated devices. A total of 56 fenestrations were incorporated, and 53 (94.6%) were successfully cannulated and stented. One patient died of bowel ischemia caused by occlusion of the superior mesenteric artery. On completion angiography, three type I endoleaks and seven type II endoleaks were observed. At 1 month of follow-up, all endoleaks had spontaneously resolved. Median follow-up was 11 months (range, 1-29 months). There were no aneurysm ruptures or aneurysm-related deaths and no reinterventions to date. Primary patency at 1 month of cannulated and stented target vessels was 96%.ConclusionsInitial and short-term results of FEVAR using the fenestrated Anaconda endograft are promising, with acceptable technical success and short-term complication rates. Growing experience and long-term results are needed to support these findings.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Vascular Surgery - Volume 60, Issue 2, August 2014, Pages 301-307
نویسندگان
, , , , , , , , , , , , , ,