Brief ReportsTracheal Tube Position Shift During Infant Resuscitation by Chest Compression: A Simulation Comparison by Fixation Method and With or Without Cuff
ترجمه فارسی عنوان
گزارشات مختصات تغییر موقعیت لوله در اطفال هنگام احیا نوزادان بوسیله کمپوست قفسه سینه: مقایسه شبیه سازی با روش ثابت و با یا بدون کاف
کلمات کلیدی
لوله تراشه، تغییر موقعیت، فشرده سازی قفسه سینه نوزاد، تثبیت لوله، شبیه سازی،
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
چکیده انگلیسی

BackgroundTracheal tube placement during infant resuscitation is essential for definite airway protection. Accidental extubation due to tracheal tube displacement is a rare event, but it results in severe complications, especially in infants.ObjectiveThe present study evaluated how infant tracheal tube displacement is affected by tape vs. tube holder fixation using a manikin.MethodsA tracheal tube with internal diameter of 3.5 mm was placed 10 cm from the gum ridge in an advanced life support (ALS) Baby® simulator (Laerdal, Stavanger, Norway). In the first trial, cuff pressure was set at 15, 20, and 25 cmH2O and trials were performed at each setting with no fixation, Durapore® (3M, St Paul, MN) tape fixation, Multipore® (3M) tape fixation, and Thomas® Tube Holder (Laerdal) fixation. After 5 min of chest compression, the tracheal tube shift was measured. In the second trial, we compared the tube shift by chest compression with or without cuff in the same way.ResultsRelative to no fixation, tracheal tube shift was significantly less in the Durapore, Multipore, and tube holder groups (p < 0.05) at all cuff settings. Of the three fixation methods, the tube holder showed significantly less shift (p < 0.05) relative to tape, regardless of the initial cuff pressure. The positional shift after chest compressions was significantly larger in the trials with cuff than in those without cuff in Durapore or Multipore fixation (p < 0.05), but did not in tube holder fixation.ConclusionsThere is less tracheal tube displacement with tube holder fixation than with tape during continuous infant chest compression simulation. The tube cuff can contribute to the positional shift of the tube during infant chest compression.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Emergency Medicine - Volume 50, Issue 4, April 2016, Pages 601-606